41 research outputs found

    Morphology of coronary artery lesions assessed by virtual histology intravascular ultrasound tissue characterization and fractional flow reserve

    Get PDF
    Fractional flow reserve (FFR) is an index of the physiological significance of a coronary stenosis. Patients who have lesions with a FFR of >0.80, even optimally treated with medication, have however a MACE rate ranging from 8 to 21%. Coronary plaques at high risk of rupture and clinical events can be also identified by virt

    Coronary plaque composition as assessed by greyscale intravascular ultrasound and radiofrequency spectral data analysis

    Get PDF
    Objectives: (i) To explore the relation between greyscale intravascular ultrasound (IVUS) plaque qualitative classification and IVUS radiofrequency data (RFD) analysis tissue types; (ii) to evaluate if plaque composition as assessed by RFD analysis can be predicted by visual assessment of greyscale IVUS images. Methods: In 120 IVUS-RFD cross-sections, a sector of the plaque with homogenous tissue composition (e.g., fibrous, fibrofatty, necrotic core, and dense calcium) was selected. Two experienced observers analyzed twice the corresponding greyscale IVUS images to: (1) classify the selected sectors according to greyscale IVUS plaque type classification and (2) predict the tissue type expected in the sector by RFD analysis. Results: In the greyscale IVUS plaque type classification, the observers agreed in 90/120 sectors (κ = 0.64). Calcified, soft and mixed plaques by greyscale IVUS classification were mainly composed of dense calcium, fibrofatty, and necrotic core, respectively, in the RFD analysis. The plaques classified in greyscale IVUS as fibrous were actually fibrous tissue by IVUS RFD in only 30% of the cases. Overall, high interobserver variability in the prediction of RFD results by visual assessment of greyscale IVUS images (κ = 0.23 for observer 1 and 0.55 for observer 2) was found. Sens

    Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies

    Get PDF
    Objectives: The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease. Background: Intravascular optical coherence tomography (IVOCT) is a catheter-based modality that acquires images at a resolution of ∼10 μm, enabling visualization of blood vessel wall microstructure in vivo at an unprecedented level of detail. IVOCT devices are now commercially available worldwide, there is an active user base, and the interest in using this technology is growing. Incorporation of IVOCT in research and daily clinical practice can be facilitated by the development of uniform terminology and consensus-based standards on use of the technology, interpretation of the images, and reporting of IVOCT results. Methods: The IWG-IVOCT, comprising more than 260 academic and industry members from Asia, Europe, and the United States, formed in 2008 and convened on the topic of IVOCT standardization through a series of 9 national and international meetings. Results: Knowledge and recommendations from this group on key areas within the IVOCT field were assembled to generate this consensus document, authored by the Writing Committee, composed of academicians who have participated in meetings and/or writing of the text. Conclusions: This document may be broadly used as a standard reference regarding the current state of the IVOCT imaging modality, intended for researchers and clinicians who use IVOCT and analyze IVOCT data

    Hyperoxemia and excess oxygen use in early acute respiratory distress syndrome : Insights from the LUNG SAFE study

    Get PDF
    Publisher Copyright: © 2020 The Author(s). Copyright: Copyright 2020 Elsevier B.V., All rights reserved.Background: Concerns exist regarding the prevalence and impact of unnecessary oxygen use in patients with acute respiratory distress syndrome (ARDS). We examined this issue in patients with ARDS enrolled in the Large observational study to UNderstand the Global impact of Severe Acute respiratory FailurE (LUNG SAFE) study. Methods: In this secondary analysis of the LUNG SAFE study, we wished to determine the prevalence and the outcomes associated with hyperoxemia on day 1, sustained hyperoxemia, and excessive oxygen use in patients with early ARDS. Patients who fulfilled criteria of ARDS on day 1 and day 2 of acute hypoxemic respiratory failure were categorized based on the presence of hyperoxemia (PaO2 > 100 mmHg) on day 1, sustained (i.e., present on day 1 and day 2) hyperoxemia, or excessive oxygen use (FIO2 ≥ 0.60 during hyperoxemia). Results: Of 2005 patients that met the inclusion criteria, 131 (6.5%) were hypoxemic (PaO2 < 55 mmHg), 607 (30%) had hyperoxemia on day 1, and 250 (12%) had sustained hyperoxemia. Excess FIO2 use occurred in 400 (66%) out of 607 patients with hyperoxemia. Excess FIO2 use decreased from day 1 to day 2 of ARDS, with most hyperoxemic patients on day 2 receiving relatively low FIO2. Multivariate analyses found no independent relationship between day 1 hyperoxemia, sustained hyperoxemia, or excess FIO2 use and adverse clinical outcomes. Mortality was 42% in patients with excess FIO2 use, compared to 39% in a propensity-matched sample of normoxemic (PaO2 55-100 mmHg) patients (P = 0.47). Conclusions: Hyperoxemia and excess oxygen use are both prevalent in early ARDS but are most often non-sustained. No relationship was found between hyperoxemia or excessive oxygen use and patient outcome in this cohort. Trial registration: LUNG-SAFE is registered with ClinicalTrials.gov, NCT02010073publishersversionPeer reviewe

    Characterization of edge effects with paclitaxel-eluting stents using serial intravascular ultrasound radiofrequency data analysis: The BETAX (BEside TAXus) study

    No full text
    Introduction and objectives. At present, the effect of paclitaxel on tissue structure at the edges of Taxus® stents is unknown. The objective of this study was to investigate in vivo the temporal changes occurring at the edges of paclitaxel-eluting stents using intravascular ultrasound radiofrequency (IVUS-RF) data analysis. Methods. The study included 24 patients who had a total of 26 paclitaxel-eluting stented segments. In all patients, IVUS-RF imaging was performed 5 mm proximally and 5 mm distally to the stent edges 6 months after stent implantation. For subsequent analysis, proximal and distal segments were divided into five 1-mm subsegments. Results. In the first two subsegments adjacent to the proximal edge of the stent, the vessel wall had grown to compensate for plaque growth without affecting the vessel lumen, while in the remaining three subsegments there was overcompensation (i.e., the vessel wall increased to greater than the plaque size). Consequently, the lumen had increased in size. At the distal edge of the stent, overcompensation was observed in all five subsegments and the lumen had increased in size. In general, proximal and distal growth was due to an increase in fibrolipid plaque (P<.001 and P<.001, respectively) along with a decrease in the necrotic core (P=.014 and P<.001, respectively) and the presence of dense calcium (P<.001 and P<.001, respectively). Conclusions. Serial expansive vascular remodeling was observed at proximal and distal stent edges. Remodeling occurred in response to tissue growth, which was mainly due to increased fibrofatty tissue

    nterventional Cardiologists of T. Impact of sex on 3-year outcome after percutaneous coronary intervention using bare-metal and drug-eluting stents in previously untreated coronary artery disease: insights from the RESEARCH (Rapamycin-Eluting Stent Evaluated at Rotterdam Cardiology Hospital) and T-SEARCH (Taxus-Stent Evaluated at Rotterdam Cardiology Hospital) Registries

    Get PDF
    ObjectivesWe investigated the impact of sex on outcomes after percutaneous coronary intervention (PCI) with drug-eluting stent (DES).BackgroundWomen have a higher risk of adverse outcomes after PCI than do men. However, long-term outcomes of women after contemporary PCI with DES have not been fully investigated.MethodsWe performed a retrospective cohort study of 4,936 consecutive patients (28.2% women) who underwent PCIs between 2000 and 2004, before and after introduction of DES (bare-metal stent [BMS] group: n = 2,131, DES group: n = 2,805), to assess the impact of sex on long-term PCI outcomes and to compare outcome after PCI of women between the DES and BMS eras.ResultsCompared with men, women undergoing PCIs were 5 years older and more frequently have comorbidities such as diabetes mellitus and hypertension. In patients treated throughout the BMS and DES eras, there were no differences by sex for risk of all-cause death, myocardial infarction, or target vessel revascularization 3 years after procedure. The procedural complexity was higher in the DES era, nevertheless, risk for target vessel revascularization and major adverse cardiac event at 3 years were significantly lower in women treated with DES than in women treated with BMS (adjusted hazard ratio [HR] for target vessel revascularization: 0.52 [95% confidence interval (CI): 0.36 to 0.75], adjusted HR for major adverse cardiac event: 0.63 [95% CI: 0.48 to 0.83]).ConclusionsAlthough women had worse baseline characteristics, no differences in 3-year outcomes were observed between men and women. Compared with BMS use, DES use has decreased revascularization rate equally in women and men

    Assessment of the absorption process following bioabsorbable everolimus-eluting stent implantation: Temporal changes in strain values and tissue composition using intravascular ultrasound radiofrequency data analysis A substudy of the ABSORB clinical trial

    No full text
    Aims: The main objective was to use IVUS-backscatter radiofrequency (IVUS-RF) to assess the degradation of a bioabsorbable stent by measuring serial changes in dense calcium (DC) and necrotic core (NC) as assessed by intravascular ultrasound-Virtual Histology™ (IVUS-VH) and in the strain as assessed by palpography. Methods and results: In the ABSORB trial, 27 patients treated with a single bioabsorbable everolimuseluting stent (BVS, Abbott Vascular, Santa Clara, CA, USA) were all imaged with IVUS-RF post-
    corecore